Rainwater Prefilter Hydraulic Verification

via Freelancer ·

Budget / Salary€30–250
TypeFreelance project
LocationRemote
Posted58 minutes ago
I need a hydraulic engineer to verify and finalise a custom rainwater prefilter before fabrication, for a residential rainwater harvesting system in Italy.

The installation has two separate drainage lines, each serving approximately 250–260 m² of roof and feeding its own Rototec CI8300 storage tank. Each tank has a Rototec Compact self-cleaning filter with Ø125 connections.

The scope covers both prefilters, F1 and F2. They use the same operating concept.

Proposed configuration of each prefilter:
- Circular chamber, approximately 790 mm internal diameter.
- Ø200 inlet, internal pipe invert at +410 mm.
- Ø200 bypass outlet, opposite the inlet, invert at +380 mm.
- Ø160 filtered-water outlet, positioned 90° from the inlet/bypass axis, invert at +300 mm.
- All these elevations are measured from the internal chamber floor.
- Removable cylindrical stainless-steel mesh between inlet and bypass, approximately Ø200 × 690 mm long. Water passes through the mesh into the surrounding chamber; debris continues towards the bypass.
- Filtered-water connection: 1 metre of Ø160 pipe at 1% slope, followed by an eccentric Ø160→125 reduction with aligned pipe inverts, entering the tank’s Compact filter.
- The Compact reject/bypass outlet is Ø125 and joins the external bypass drainage downstream.
- Two separate discharge pipelines run approximately 50 metres towards a ditch, with an available slope of approximately 0.5–0.6%.
Main objective:
Keep the discharge to the ditch as high as practicable while obtaining a quantified, acceptable rainwater recovery rate. Maximum collection efficiency is not mandatory, but the trade-off must be calculated.

Required checks:
1. Verify the proposed inlet, bypass and filtered-outlet elevations.
2. Calculate the flow split between filtered water and direct bypass over a range of incoming flows.
3. Include mesh losses, partial blockage, entrance losses, pipe friction, fittings, the reduction and the downstream Compact filter.
4. Assess whether turbulence and direct flow through the cylindrical mesh cause excessive water loss to bypass.
5. Check the downstream Ø125 bypass connection and identify conditions that could cause backflow.
6. Identify any missing manufacturer data or measurements needed before final approval.
Deliverables:
- Calculation report stating assumptions, methods and limitations.
- Flow table showing inlet flow, flow reaching storage and bypass flow.
- Dimensioned plan and section showing recommended pipe invert elevations.
- Recommended mesh specification and any necessary geometry changes.
- Practical commissioning test procedure.
I will provide existing drawings, drainage calculations, site elevations, photographs and available manufacturer documentation.

Please describe relevant experience with gravity drainage, rainwater harvesting and self-cleaning filters. Explain your proposed calculation method and whether physical testing or manufacturer performance data will be required. Please quote a fixed price and delivery time.
mechanical engineering civil engineering water treatment environmental engineering construction engineering