Bosch Alarm Commissioning Support
Budget / SalaryHourly project
TypeFreelance project
LocationRemote
Posted1 hour ago
I have a freshly installed Bosch fire-alarm system that now needs to be fully tested, commissioned, and signed off. The exact panel hasn’t been documented yet—it could be an FPA-5000, an AVENAR variant, or another current Bosch model—so the first step will be identifying the hardware and firmware on site.
The installation spans a mixed-use complex that combines office and retail areas, an apartment wing with hotel-style amenities, a small healthcare clinic, plus a light-industrial warehouse. Every loop is wired and devices are mounted; what’s missing is the expertise to bring the system to life, demonstrate compliance, and hand over clear documentation to the local authority and my facilities team.
Here’s what I need from you:
• Arrive (or remote-in, if practical) to verify panel model and firmware
• Program all zones, cause-and-effect, and evacuation sequences using the required Bosch tools (RPS, Avenar Programming Suite, etc.)
• Perform 100 % device testing, fault rectification where necessary, and final acceptance tests
• Generate and supply commissioning certificates, device lists, and the final configuration file
Acceptance criteria: the system must pass the full commissioning checklist with no outstanding faults, all documentation must be delivered in PDF and native Bosch format, and the panel must operate to agreed cause-and-effect across every occupancy type in the building.
If you have proven experience with Bosch panels and can meet those deliverables, I’m ready to schedule the work immediately.
The installation spans a mixed-use complex that combines office and retail areas, an apartment wing with hotel-style amenities, a small healthcare clinic, plus a light-industrial warehouse. Every loop is wired and devices are mounted; what’s missing is the expertise to bring the system to life, demonstrate compliance, and hand over clear documentation to the local authority and my facilities team.
Here’s what I need from you:
• Arrive (or remote-in, if practical) to verify panel model and firmware
• Program all zones, cause-and-effect, and evacuation sequences using the required Bosch tools (RPS, Avenar Programming Suite, etc.)
• Perform 100 % device testing, fault rectification where necessary, and final acceptance tests
• Generate and supply commissioning certificates, device lists, and the final configuration file
Acceptance criteria: the system must pass the full commissioning checklist with no outstanding faults, all documentation must be delivered in PDF and native Bosch format, and the panel must operate to agreed cause-and-effect across every occupancy type in the building.
If you have proven experience with Bosch panels and can meet those deliverables, I’m ready to schedule the work immediately.
Apply on Freelancer →
Project sourced from Freelancer.com. Applications happen directly on the original platform — we never collect your data.